Agri / Pressure  Piping Systems

Agri / Pressure Piping Systems

  • Light weight, easy to transport

    Light weight, easy to transport

  • Smooth bore ensures higher flow

    Smooth bore ensures higher flow

  • Long working life

    Long working life

  • Cost effective

    Cost effective

Agri / Pressure Piping Systems

AKG offers an exhaustive range of uPVC pressure pipes & fittings. Pressure pipes are manufactured as per IS 4985:2000 standard and are available in 20 mm to 315 mm sizes in different pressure class. Pipes with both types of joints i.e. solvent cement type and elastomeric rubber seal type joints are available. Varieties of moulded fittings and wide range of fabricated fittings are also available. Moulded fittings are manufactured as per IS 7834:1987 These pipes and fittings are used for variety of applications like, agriculture, irrigation, water supply, industrial process lines, swimming pools and fire fighting mains etc. These pipes are superior to C.I , D.I or R.C.C pipes and offers number of advantages like light weight, easy and fast installation, excellent corrosion and chemical resistance, high flow rates, long life and economy.

Nominal Outside Diameter
(Nominal Size)
Mean Outside Diameter Class 1
0.25 Mpa
Class 2
0.4 Mpa
Class 3
0.6 Mpa
Class 4
0.8 Mpa
Class 5
1.0 Mpa
Class 6
1.25 Mpa
Min Max Min Max Min Max Min Max Min Max Min Max Min Max
20 20.0 20.3 - - - - - - - - 1.1 1.5 1.4 1.9
25 25.0 25.3 - - - - - - 1.2 1.6 1.4 1.8 1.7 2.1
32 32.0 32.3 - - - - - - 1.5 1.9 1.8 2.2 2.2 2.7
40 40.0 40.3 - - - - 1.4 1.8 1.8 2.2 2.2 2.7 2.8 3.3
50 50.0 50.3 - - - - 1.7 2.1 2.3 2.8 2.8 3.3 3.4 4.0
63 63.0 63.3 - - 1.5 1.9 2.2 2.7 2.8 3.3 3.5 4.1 4.3 5.0
75 75.0 75.3 - - 1.8 2.2 2.6 3.1 3.4 4.0 4.2 4.9 5.1 5.9
90 90.0 90.3 1.3 1.7 2.1 2.6 3.1 3.7 4.0 4.6 5.0 5.7 6.1 7.1
110 110.0 110.4 1.6 2.0 2.5 3.0 3.7 4.3 4.9 5.6 6.1 7.1 7.5 8.7
125 125.0 125.4 1.8 2.2 2.9 3.4 4.3 5.0 5.6 6.4 6.9 8.0 8.5 9.8
140 140.0 140.5 2.0 2.4 3.2 3.8 4.8 5.5 6.3 7.3 7.7 8.9 9.5 11.0
160 160.0 160.5 2.3 2.8 3.7 4.3 5.4 6.2 7.2 8.3 8.8 10.2 10.9 12.6
180 180.0 180.6 2.6 3.1 4.2 4.9 6.1 7.1 8.0 9.2 9.9 11.4 12.2 14.1
200 200.0 200.6 2.9 3.4 4.6 5.3 6.8 7.9 8.9 10.3 11.0 12.7 13.6 15.7
225 225.0 225.7 3.3 3.9 5.2 6.0 7.6 8.8 10.0 11.5 12.4 14.3 15.3 17.6
250 250.0 250.8 3.6 4.2 5.7 6.5 8.5 9.8 11.2 12.9 13.8 15.9 17.0 19.6
280 280.0 280.9 4.1 4.8 6.4 7.4 9.5 11.0 12.5 14.4 15.4 17.8 19.0 21.9
315 315.0 316.0 4.6 5.3 7.2 8.3 10.7 12.4 14.0 16.1 17.3 19.9 21.4 24.7

Fittings

• General Dimensions confirming to IS 7834:1987.

• Wall thickness is designed to meet required working pressure made to close dimensional tolerance.

• Wide range for different applications

Jointing Method

Cut the pipe as square as possible. Please ensure that fitment of pipe with socket of fitting is correct.

 

Total length of insertion of socket shall be marked on pipe(for most of the cases the pipe inserted should be up to the marked line and in no case shall be less than 2/3rd of the pipe end up to the marked line).

 

The pipe and the socket should be clean and dry. Dust, oil, water, grease etc should be wiped out with dry cloth or cleaner from the surfaces to be coated with solvent cement.

 

Roughen the outside of the pipe and the inside of the socket using sand paper or piece of hacksaw blade up to the entry mark. Stir adhesive i.e. solvent cement thoroughly.

 

Apply a thick coat of suitable grade of good quality solvent cement. Using a flat clean brush evenly on the inside of the socket mouth for full length of insertion. And then on outside of the pipe, end up to the marked line.

 

After application of solvent cement, insert the pipe within one minute into the socket. Hold the joint for few seconds and ensure that pipe does not come out of the fitting. Wipe off extra cement. Let it dry. Within 24 hours, your AKG rigid PVC pipes are ready for use.

 

Clean the inside of socket. Remove all traces of mud, dirt, grease, gravel and clean elastomeric sealing ring.

 

If pipe need to be cut, it should be cut perpendicular to the axis of the pipe. Then it should be chamfered properly.

 

Form the ring into a heart shape by pinching a portion of ring from inside. Insert into the socket and release to seat into the groove.

 

Push the spigot into the socket until it reaches the depth of entry mark, do not over insert. This must be done manually. Insertion of spigot end inside the socket should be at the correct angle.

 

Specifications

  Fittings Pipes
Material Unplasticized Polyvinyl
Chloride(UPVC)
Unplasticized Polyvinyl
Chloride (UPVC)
Colour Light Grey Light Grey
Reference Standards IS 7834 : 1987 IS 4985 : 2000
Working Temperature of fluids Upto 60 degree- Continuous
Upto 90 degree- Short Time
-upto 3 mins
Upto 60 degree- Continous
Upto 90 degree- Short Time
-upto 3 mins
Working Temperature (gk/cm2) 4, 6, 10 & 16 2.5, 4, 6, 10 & 12
End Connections Solvent sockets, Threads
(For transition fittings)
Solvent sockets,
Rubber Ring sockets

© Copyright- AKG Group of Companies. All Rights Reserved. Powered By ITPL